Send Message
Home ProductsAir to Water Heat Pump

Split On-Off Heat Pump Water Heater -B1 (R134A)

I'm Online Chat Now

Split On-Off Heat Pump Water Heater -B1 (R134A)

Split On-Off Heat Pump Water Heater -B1 (R134A)
Split On-Off Heat Pump Water Heater -B1 (R134A)

Large Image :  Split On-Off Heat Pump Water Heater -B1 (R134A)

Product Details:
Place of Origin: China
Brand Name: Deakonet
Certification: CE
Model Number: 4.5/5.6/7.5/9/12/15kW Models
Payment & Shipping Terms:
Minimum Order Quantity: 5
Packaging Details: Playwood box
Delivery Time: 10-15 Working Days
Payment Terms: ,L/C,T/T
Supply Ability: 30,000 Units/Year
Detailed Product Description
COP: 4.0 Compressor: Panasonic On-Off Compressor
Refrigerant: R134A Condenser: High-Efficiency Tank Heat Exchanger.
Fan Motor: AC Circulation Pump: Optional Built-in On-Off Water Pump
Control: WIFI +APP +4.3/5 Inch Touch Screen Panel Function: Hot Water
Maximum Outlet Water Temperature: 75℃

What is an air source heat pump?Split On-Off Heat Pump Water Heater -B1 (R134A) 0


  • An air source heat pump (ASHP) is a heating and cooling system that extracts heat from the ambient air and transfers it indoors or outdoors, depending on the desired effect. 

It uses the principles of refrigeration to absorb heat from the outside air and deliver it inside a building for heating water tank and room purposes. 

During hot weather, the process can be reversed to provide cooling by extracting heat from inside and releasing it outside. 

ASHPs are known for their energy efficiency and can be used in residential, commercial and industrial settings. They are considered a renewable and environmentally-friendly alternative to traditional heating and cooling systems.


Features of The B1 Series Heat Pump Water Heater


  • Split On-Off Heat Pump Water Heater -B1 (R134A) 1 High Efficiency:  The B1 series heat pump water heater uses a high-efficiency Panasonic compressor combined with the efficient heat exchangers for optimal performance.

  • Split On-Off Heat Pump Water Heater -B1 (R134A) 2High Water Temperature Range: The B1 series Heat pump water heaters can typically provide water temperatures between 45-75°C, whichSplit On-Off Heat Pump Water Heater -B1 (R134A) 3 is suitable for most household hot water needs.


  • Split On-Off Heat Pump Water Heater -B1 (R134A) 4Safety: The B1 series heat pump water heater is designed with advanced safety features to ensure reliable and secure operation.  It includes a built-in high and low-pressure protection system, preventing potential risks from pressure fluctuations.  The unit also comes equipped with an automatic anti-freezing function to protect against low-temperature damage, as well as a safety valve to prevent excessive pressure buildup.  Additionally, it has an overheat protection mechanism to avoid overheating and safeguard the internal components, ensuring long-term safe usage for both residential and commercial applications.


  • Split On-Off Heat Pump Water Heater -B1 (R134A) 5Smart Control: The B1 series heat pump come with advanced features such as Wi-Fi smart phone APP control, allowing users to monitor and adjust settings remotely via smartphone apps.



  • Easy installation: Optional integrated features include a built-in circulation pump, expansion tank, and backup electric heating within the heatSplit On-Off Heat Pump Water Heater -B1 (R134A) 6 pump, making installation easier and more convenient.


  • Quiet: The B1 Series heat pump is designed with low noise operation, ensuring minimal sound disruption while providing efficient heating and cooling. Its advanced technology and optimized components help reduce noise levels, making it ideal for residential and commercial settings where quiet operation is essential.

Split On-Off Heat Pump Water Heater -B1 (R134A) 7



Line-Up

Heat Pump Model 

B1-4.5

B1-5.6

B1-7.5

B1-9.0

B1-12

B1-15

Power supply (P/V/Hz)

1/220-240V/50

3/380-415/ 50

Heating capacity at A7/W55℃ (kW)

4.5

5.6

7.5

9.0

12.0

15.0

Rated input power (kW)

1.1

1.4

1.9

2.3

3.0

3.8

COP

3.95

4.00

4.01

3.96

3.98

4.00

Heating capacity at A20/W55℃ (kW)

5.2

6.4

8.6

10.4

13.8

17.3

Rated input power (kW)

1.2

1.6

2.1

2.5

3.3

4.2

COP

4.15

4.14

4.14

4.16

4.15

4.13

Refrigerant  type 

R134a (Optional R410a/R32)

Max delivery water temp (℃)

For R134A, the maximum temperature is 75°C, while for R32 or R410A, the maximum temperature is 60°C.

Working temp range (℃)

-7℃~43℃

Water yield (L/hour) 

105

131

175

210

280

350

Noise level [dB(A)]

47

47

49

51

53

55

Dimensions 

850x295x

585

850x295x

585

870x420x

935

870x420x

935

870x370x

1375

870x370x

1375

Cabinet  

Default galvanized steel with white color painting, Optional SUS 304 stainless steel 

Split On-Off Heat Pump Water Heater -B1 (R134A) 8

Contact Details
FOSHAN JUYANG NEW ENERGY CO LTD

Contact Person: Hansen Ro

Tel: +86 757 8562 2139

Send your inquiry directly to us (0 / 3000)

Request A Quote

E-Mail | Sitemap

Privacy Policy | China Good Quality Air to Water Heat Pump Supplier. © 2024 - 2025 heatpump-factory.com. All Rights Reserved.